GS 2600 Specifications
- 2.6GB Media (ISO/IEC 14517)
- 2.6GB at 1024 bytes/sector
- 2.3GB at 512 bytes/sector
- 1.3GB Media (ISO/IEC 13549)
- 1.3GB at 1024 bytes/sector
- 1.2GB at 512 bytes/sector
- 1.0GB Media (ISO/IEC 13481)
- 1.02GB at 1024 bytes/sector
- 926MB at 512 bytes/sector
- 650MB Media (ISO/IEC 10089)
- 650MB at 1024 bytes/sector
- 600MB at 512 bytes/sector
- 2.6GB Media (IS)/IEC 14517)
- 2.6GB at 1024 bytes/sector
- 2.3GB at 512 bytes/sector
Max read data transfer
- rate: 6MB/sec
Max sustained write speed
- MO: 2.17MB /sec
- LIMDOW: 3.5MB/sec
Rotation
- speed: 3868 RPM
- Average seek time (TYPICAL): 19ms
- Average latency: 7.8ms
- Data buffer size: 1,024KB
- Spin up time: 4.0 SEC/TYPICAL
- Spin down time: 2.5 SEC/TYPICAL
- Data read error: <1 in 10 reads
- MTBF: 200,000 power-on hours
- MIBF: 500,000
- Host interface: Sngle-ended SCSI-2
- SCSI Bus transfer rate (BURST)
- 5.0MB/sec (MAX): (ASYNC)
- 10.0MB/sec (MAX): (FAST SYNC)
Internal Power Consumption (TYP)
- Idle: 13W (AVERAGE)
- Read/Write: 21W (AVERAGE)
- Seek: 25W (PEAK)
DC Current
- + 5 V: 2.0A (TYPICAL).2.2A (MAX)
- + 12 V: 1.0A (TYPICAL) 4.0A (MAX)
External Power Requirements
- Voltage: 100-260 VAC
- Frequency: 47-63 Hz
Power consumption….30W (AVERAGE)
Dimensions (w x h x d mm
- Internal unit: 146.1 X 41.3 X 203.2 (with front bezel) 149.3 X 44.6 X 208.5
- Weight internal unit: 1.5Kg (3.3 LBS)
Temperature
- Operating: 5° C to 50° C
- Non-operating 40° C to 70° C
Relative Humidity (Non-Condensed)
- Operating: 8% to 80%
- Non-operating: 5% to 90%
Altitude
- Operating:
-300m to 3,000m..(-1,000FT to 10,000FT)
- Non-operating:
-300m to 12,000m(-1,000FT to 40,000FT)
Shock
- Operating: 35G, 3ms PULSE
- Non-operating: 50G, 11ms (1/2 SINE)
|
 |
|